Fuan Zhongzhi Pump Co., Ltd.

Fuan Zhongzhi Pump Co., Ltd. We focus on delivering reliable, value-driven AC induction motors engineered for real-world industrial applications. At ZOZHI Motors, dependable performance, cost

Manufacturer from China
Verified Supplier
9 Years
Home / Products / IE2 Motor /

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft

Contact Now
Fuan Zhongzhi Pump Co., Ltd.
Visit Website
Province/State:fujian
Contact Person:MsSemmy Wu
Contact Now

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft

Ask Latest Price
Brand Name :ZOZHI
Model Number :IE2 MS100L2-4
Certification :CE,ISO
Place of Origin :FUAN CHINA
MOQ :10pcs
Price :negotiated
Payment Terms :T/T
Supply Ability :10000pcs/month
Delivery Time :25 working days after received your payment
Packaging Details :Packed in cartons,veneer case or wooden case.
Name :IE2 Motor
Output :3kw/4Hp
Voltage :230/400V/60HZ
Winding Material :100% Copper Wire
Standard :IEC 2
Housing :Aluminum
Pole :4
Phase :3 Phase
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Three Phase Electric Motors With Male Shaft B3/B14 High-Efficiency 3 phase A.C. induction motor


Description

Three-phase electric motors are equipped with a male shaft, and they require a flexible coupling and a flange to be connected with the plunger pumps. They are designed to work with the most common pumps on the market. They are available in different versions that offer different power ranges and rotation speeds to offer a wide range of choices for pump propulsion.

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft


Application

Three-phase asynchronous motors have higher operating efficiency and better working characteristics. They run at a nearly constant speed from no-load to the full-load range and can meet the transmission requirements of most industrial and agricultural production machinery. Asynchronous motors are widely used in machine tools, water pumps, blowers, and compressors.

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft


Operating conditions
Ambient temperature: -15°C~40°C
Altitude: Altitude should be higher than 1000 meters above sea level.
Rated voltage: 380V,400V,415V,440V. Rated frequency: 50Hz,60Hz.
Connection: Y Star-connection for 3kw or less whereas and delta-connection.
Duty/Rating: Continuous (S1)
Insulation class: F, the temperature rise of the stator winding is examined at 80K
(by resistance method).
Protection class: IP55.
Cooling method: IC411.

Production Line
MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft



IE2 Motor Technical Data

Model Power (V) (A) (r/min) Eff. (%) P.F. Ist/In Tmax/Tn
Kw HP 50% 75% 100%
IE2 MS801-2 0.75 1 230/400 3.0/1.73 2800 76.5 77.3 77.4 0.813 2.2 2.3
IE2 MS802-2 1.1 1.5 4.2/2.43 2800 79 80 79.6 0.825 2.2 2.3
IE2 MS90S-2 1.5 2 5.53/3.19 2820 80.2 81.5 81.3 0.837 2.2 2.3
IE2 MS90L-2 2.2 3 7.93/4.58 2820 82.2 83.5 83.2 0.837 2.2 2.3
IE2 MS100L-2 3 4 10.5/6.06 2830 84 85.1 84.6 0.848 2.2 2.3
IE2 MS112M-2 4 5.5 400/690 7.97/4.6 2850 85.4 86.8 85.8 0.848 2.2 2.3
IE2 MS132S1-2 5.5 7.5 10.65/6.15 2870 86.7 87.3 87 0.86 2 2.3
IE2 MS132S2-2 7.5 10 14.35/8.28 2870 87.6 88.3 88.1 0.86 2 2.3
IE2 MS160M1-2 11 15 20.74/11.97 2900 89 89.8 89.4 0.86 2 2.3
IE2 MS160M2-2 15 20 27.99/16.16 2900 90 90.5 90.3 0.86 2 2.3
IE2 MS160L-2 18.5 25 33.83/19.53 2900 90.3 91 90.9 0.872 2 2.2
IE2 MS802-4 0.75 1 230/400 3.28/1.9 1380 77.3 79.8 79.6 0.72 2.3 2.3
IE2 MS90S-4 1.1 1.5 4.57/2.64 1400 79.9 81.7 81.4 0.743 2.3 2.3
IE2 MS90L-4 1.5 2 6.02/3.48 1400 82.1 83.5 82.8 0.755 2.3 2.3
IE2 MS100L1-4 2.2 3 8.42/4.86 1420 82.6 84.5 84.3 0.778 2.2 2.3
IE2 MS100L2-4 3 4 11.32/6.54 1420 84.2 85.7 85.5 0.778 2.2 2.3
IE2 MS112M-4 4 5.5 400/690 8.47/4.89 1430 85.8 87 86.6 0.79 2.2 2.3
IE2 MS132S-4 5.5 7.5 11.18/6.45 1450 87.4 88.3 87.7 0.813 2.2 2.3
IE2 MS132M-4 7.5 10 14.85/8.58 1450 88.2 89 88.7 0.825 2.2 2.3
IE2 MS160M-4 11 15 21.84/12.61 1460 89.1 90 89.8 0.813 2.2 2.3
IE2 MS160L-4 15 20 29.08/16.79 1460 90.2 91.1 90.6 0.825 2.2 2.3
IE2 MS90S-6 0.75 1 230/400 3.82/2.2 910 73.4 76.3 75.9 0.65 2 2.2
IE2 MS90L-6 1.1 1.5 5.25/3.03 910 77 78.8 78.1 0.673 2 2.2
IE2 MS100L-6 1.5 2 6.77/3.91 940 79.6 80.8 79.8 0.697 2 2.2
IE2 MS112M-6 2.2 3 9.69/5.59 940 80.4 81.6 81.8 0.697 2 2.2
IE2 MS132S-6 3 4 12.56/7.25 960 81 83.4 83.3 0.72 2 2.2
IE2 MS132M1-6 4 5.5 400/690 9.36/5.4 960 82.7 84.5 84.6 0.732 2 2.2
IE2 MS132M2-6 5.5 7.5 12.47/7.2 960 84.8 86.2 86 0.743 2 2.2
IE2 MS160M-6 7.5 10 16.78/9.69 970 86.4 87.5 87.2 0.743 2 2
IE2 MS160L-6 11 15 24.19/13.97 970 88.2 89.2 88.7 0.743 2 2


Performance comparison chart:

ELECTRIC MOTOR EFFICIENCY VALUES-4POLES 1500 RPM
Power(kw) eff2 (nominal) eff1 (nominal) IE2 (nominal) IE3 (nominal)
0.75 - - 79.6 82.5
1.1 76.2 83.8 81.4 84.1
1.5 78.5 85.0 82.8 85.3
2.2 81 86.4 84.3 86.7
3.0 82.6 87.4 85.5 87.7
4.0 84.2 88.3 86.6 88.6
5.5 85.7 89.2 87.7 89.6
7.5 87 90.1 88.7 90.4
11 88.4 91.0 89.8 91.4
15 89.4 91.8 90.6 92.1
18.5 90 92.2 91.2 92.6
22 90.5 82.6 91.6 93.0
30 91.4 93.2 92.3 93.8
37 92 93.6 92.7 93.9
45 92.5 93.9 93.1 94.2
55 93 94.2 93.5 94.6
75 93.6 94.7 94.0 95.0
90 93.9 95.0 94.2 95.2
110 94.5 95.4
132 94.7 95.6
160 94.9 95.8
200...375 95.1 96.0

Common Faults With AC Motors

We often see the same faults with A.C. motors, below and some of the most common faults with A.C. motors and how you can identify them.

Fault Notice
Open Circuit on Windings Motor Buzzes or Hums and won’t work
Earth Fault Motor Dead and won’t work
Bearing Failing Noise, Vibration, Excess Heat on Drive End or Non-Drive End
Bearing Collapse Shaft Damage, Core Damage, Winding Damage
Rotor Problems Movement in Shaft, Bearing Journals undersized.
Misalignment Premature Coupling Failures, Vibration of Motor
Bent Shaft Early Bearing Failures, Vibration

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft

MS100L2-4 3kw/4hp IE2 Motor , 3 Phase AC Induction Motor With Male Shaft

Inquiry Cart 0