Add to Cart
Description
Three-phase electric motors are equipped with a male shaft, and they require a flexible coupling and a flange to be connected with the plunger pumps. They are designed to work with the most common pumps on the market. They are available in different versions that offer different power ranges and rotation speeds to offer a wide range of choices for pump propulsion.
Application
Three-phase asynchronous motors have higher operating efficiency and better working characteristics. They run at a nearly constant speed from no-load to the full-load range and can meet the transmission requirements of most industrial and agricultural production machinery. Asynchronous motors are widely used in machine tools, water pumps, blowers, and compressors.
Operating conditions
Ambient temperature: -15°C~40°C
Altitude: Altitude should be higher than 1000 meters above sea level.
Rated voltage: 380V,400V,415V,440V. Rated frequency: 50Hz,60Hz.
Connection: Y Star-connection for 3kw or less whereas and delta-connection.
Duty/Rating: Continuous (S1)
Insulation class: F, the temperature rise of the stator winding is examined at 80K
(by resistance method).
Protection class: IP55.
Cooling method: IC411.
IE2 Motor Technical Data
Model | Power | (V) | (A) | (r/min) | Eff. (%) | P.F. | Ist/In | Tmax/Tn | |||
Kw | HP | 50% | 75% | 100% | |||||||
IE2 MS801-2 | 0.75 | 1 | 230/400 | 3.0/1.73 | 2800 | 76.5 | 77.3 | 77.4 | 0.813 | 2.2 | 2.3 |
IE2 MS802-2 | 1.1 | 1.5 | 4.2/2.43 | 2800 | 79 | 80 | 79.6 | 0.825 | 2.2 | 2.3 | |
IE2 MS90S-2 | 1.5 | 2 | 5.53/3.19 | 2820 | 80.2 | 81.5 | 81.3 | 0.837 | 2.2 | 2.3 | |
IE2 MS90L-2 | 2.2 | 3 | 7.93/4.58 | 2820 | 82.2 | 83.5 | 83.2 | 0.837 | 2.2 | 2.3 | |
IE2 MS100L-2 | 3 | 4 | 10.5/6.06 | 2830 | 84 | 85.1 | 84.6 | 0.848 | 2.2 | 2.3 | |
IE2 MS112M-2 | 4 | 5.5 | 400/690 | 7.97/4.6 | 2850 | 85.4 | 86.8 | 85.8 | 0.848 | 2.2 | 2.3 |
IE2 MS132S1-2 | 5.5 | 7.5 | 10.65/6.15 | 2870 | 86.7 | 87.3 | 87 | 0.86 | 2 | 2.3 | |
IE2 MS132S2-2 | 7.5 | 10 | 14.35/8.28 | 2870 | 87.6 | 88.3 | 88.1 | 0.86 | 2 | 2.3 | |
IE2 MS160M1-2 | 11 | 15 | 20.74/11.97 | 2900 | 89 | 89.8 | 89.4 | 0.86 | 2 | 2.3 | |
IE2 MS160M2-2 | 15 | 20 | 27.99/16.16 | 2900 | 90 | 90.5 | 90.3 | 0.86 | 2 | 2.3 | |
IE2 MS160L-2 | 18.5 | 25 | 33.83/19.53 | 2900 | 90.3 | 91 | 90.9 | 0.872 | 2 | 2.2 | |
IE2 MS802-4 | 0.75 | 1 | 230/400 | 3.28/1.9 | 1380 | 77.3 | 79.8 | 79.6 | 0.72 | 2.3 | 2.3 |
IE2 MS90S-4 | 1.1 | 1.5 | 4.57/2.64 | 1400 | 79.9 | 81.7 | 81.4 | 0.743 | 2.3 | 2.3 | |
IE2 MS90L-4 | 1.5 | 2 | 6.02/3.48 | 1400 | 82.1 | 83.5 | 82.8 | 0.755 | 2.3 | 2.3 | |
IE2 MS100L1-4 | 2.2 | 3 | 8.42/4.86 | 1420 | 82.6 | 84.5 | 84.3 | 0.778 | 2.2 | 2.3 | |
IE2 MS100L2-4 | 3 | 4 | 11.32/6.54 | 1420 | 84.2 | 85.7 | 85.5 | 0.778 | 2.2 | 2.3 | |
IE2 MS112M-4 | 4 | 5.5 | 400/690 | 8.47/4.89 | 1430 | 85.8 | 87 | 86.6 | 0.79 | 2.2 | 2.3 |
IE2 MS132S-4 | 5.5 | 7.5 | 11.18/6.45 | 1450 | 87.4 | 88.3 | 87.7 | 0.813 | 2.2 | 2.3 | |
IE2 MS132M-4 | 7.5 | 10 | 14.85/8.58 | 1450 | 88.2 | 89 | 88.7 | 0.825 | 2.2 | 2.3 | |
IE2 MS160M-4 | 11 | 15 | 21.84/12.61 | 1460 | 89.1 | 90 | 89.8 | 0.813 | 2.2 | 2.3 | |
IE2 MS160L-4 | 15 | 20 | 29.08/16.79 | 1460 | 90.2 | 91.1 | 90.6 | 0.825 | 2.2 | 2.3 | |
IE2 MS90S-6 | 0.75 | 1 | 230/400 | 3.82/2.2 | 910 | 73.4 | 76.3 | 75.9 | 0.65 | 2 | 2.2 |
IE2 MS90L-6 | 1.1 | 1.5 | 5.25/3.03 | 910 | 77 | 78.8 | 78.1 | 0.673 | 2 | 2.2 | |
IE2 MS100L-6 | 1.5 | 2 | 6.77/3.91 | 940 | 79.6 | 80.8 | 79.8 | 0.697 | 2 | 2.2 | |
IE2 MS112M-6 | 2.2 | 3 | 9.69/5.59 | 940 | 80.4 | 81.6 | 81.8 | 0.697 | 2 | 2.2 | |
IE2 MS132S-6 | 3 | 4 | 12.56/7.25 | 960 | 81 | 83.4 | 83.3 | 0.72 | 2 | 2.2 | |
IE2 MS132M1-6 | 4 | 5.5 | 400/690 | 9.36/5.4 | 960 | 82.7 | 84.5 | 84.6 | 0.732 | 2 | 2.2 |
IE2 MS132M2-6 | 5.5 | 7.5 | 12.47/7.2 | 960 | 84.8 | 86.2 | 86 | 0.743 | 2 | 2.2 | |
IE2 MS160M-6 | 7.5 | 10 | 16.78/9.69 | 970 | 86.4 | 87.5 | 87.2 | 0.743 | 2 | 2 | |
IE2 MS160L-6 | 11 | 15 | 24.19/13.97 | 970 | 88.2 | 89.2 | 88.7 | 0.743 | 2 | 2 |
Performance comparison chart:
ELECTRIC MOTOR EFFICIENCY VALUES-4POLES 1500 RPM | ||||
Power(kw) | eff2 (nominal) | eff1 (nominal) | IE2 (nominal) | IE3 (nominal) |
0.75 | - | - | 79.6 | 82.5 |
1.1 | 76.2 | 83.8 | 81.4 | 84.1 |
1.5 | 78.5 | 85.0 | 82.8 | 85.3 |
2.2 | 81 | 86.4 | 84.3 | 86.7 |
3.0 | 82.6 | 87.4 | 85.5 | 87.7 |
4.0 | 84.2 | 88.3 | 86.6 | 88.6 |
5.5 | 85.7 | 89.2 | 87.7 | 89.6 |
7.5 | 87 | 90.1 | 88.7 | 90.4 |
11 | 88.4 | 91.0 | 89.8 | 91.4 |
15 | 89.4 | 91.8 | 90.6 | 92.1 |
18.5 | 90 | 92.2 | 91.2 | 92.6 |
22 | 90.5 | 82.6 | 91.6 | 93.0 |
30 | 91.4 | 93.2 | 92.3 | 93.8 |
37 | 92 | 93.6 | 92.7 | 93.9 |
45 | 92.5 | 93.9 | 93.1 | 94.2 |
55 | 93 | 94.2 | 93.5 | 94.6 |
75 | 93.6 | 94.7 | 94.0 | 95.0 |
90 | 93.9 | 95.0 | 94.2 | 95.2 |
110 | 94.5 | 95.4 | ||
132 | 94.7 | 95.6 | ||
160 | 94.9 | 95.8 | ||
200...375 | 95.1 | 96.0 |
Common Faults With AC Motors
We often see the same faults with A.C. motors, below and some of the most common faults with A.C. motors and how you can identify them.
Fault | Notice |
Open Circuit on Windings | Motor Buzzes or Hums and won’t work |
Earth Fault | Motor Dead and won’t work |
Bearing Failing | Noise, Vibration, Excess Heat on Drive End or Non-Drive End |
Bearing Collapse | Shaft Damage, Core Damage, Winding Damage |
Rotor Problems | Movement in Shaft, Bearing Journals undersized. |
Misalignment | Premature Coupling Failures, Vibration of Motor |
Bent Shaft | Early Bearing Failures, Vibration |